LED 3-fach Temperatur-Anzeige. Die LED Anzeige verfügt über insgesamt 3 digitale, kabelgebundene Temperaturfühler. Die jeweiligen Temperaturanzeigen selber können bis zu +-9°C eingestellt/manipuliert werden. Die Konfigurationseinstellungen werden per IR-Fernbedienung vorgenommen.
Anwendungsbereich:indoor
Schrifthöhe:65mm
max. Leseentfernung:ca. 25-30m
LED Farbe:Rot
Ansteuerung:IR-Fernbedienung
Kompakt mit zwei Kanälen bei nur bei 15mm Modulbreite
Digitale Signalfilter im Peripheriemodul
Bis zu 10kHz Abtastrate frei einstellbar
Taktsynchroner Betrieb / optional mit Oversampling
Anschluss einer Vielzahl von Sensoren durch frei einstellbaren Eingangssignalbereich
Werkskalibrierung gewährleistet problemlosen Modultausch
• According to DIN EN 61810-1, DIN EN 60664-1
• Different pin configurations and pin arrangements
• Clearance and creepage distances:
contact-coil ≥ 8 mm
• Compact size, small height (horizontal model)
• OA 5651, 5661 horizontal models
• OA 5652, 5662, 5692 vertical models
• Solder line proof
Function:Printed circuit board relay
Type of relay:monostabil
Contact material:AgSnO2; AgNi
Continuous current:8 A
Nominal voltage UN DC:6 - 60 V
Voltage Range UN:0,7 - 1,8 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:8 mm
Temperature range (- / +):40 - 80 °C
Protection type:RT II (flux-proof relay)
Size L x W x H:28 x 25 x 10,8 mm
Approvals:cRUus
Relay type:OA 5661
kalibrierte Signalumschaltung
Ein- und Ausgangssignal einfach über DIP-Schalter umschaltbar – ohne Nachjustierung
Universalnetzteil für 20 … 253 V AC/DC
weltweit einsetzbar an beliebigen Versorgungsnetzen
3-Port-Trennung
Schutz vor Messfehlern durch Erdungsprobleme und Störspannungsverschleppung
extrem kompakte Bauform
12,5 mm schmales Anreihgehäuse mit praktischen Steckklemmen
höchste Genauigkeit
keine Verfälschung des Messsignals
sichere Trennung
Schutz des Wartungspersonals und der nachfolgenden Geräte vor unzulässig hoher Spannung
höchste Zuverlässigkeit
Kosten für Wartungsaufwand entfallen
5 Jahre Garantie
Innerhalb von 5 Jahren ab Lieferung auftretende Mängel werden bei freier Anlieferung im Werk kostenlos behoben
Axial-Querstromgebläse
Noch bessere Anlagerung - weniger Abdrift und Spritzmittelverlust durch gezielte Luftführung. Daher umweltfreundlicher und effektiver.
Top-Serienausrüstung
- mech. Bedieneinheit mit Bowdenzügen
- Saugfilter mit Absperrautomatik
- Druckfilter mit Schnellreinigung
- Behälterfüllstandsanzeige
- Hydr. Rührwerk
- Spülbehälter zur Systemreinigung
- Handwaschbehälter 15 l
- Behälterauslaufhahn
- Gebläse abschaltbar
- Myers-Einzeldüsen mit Tropf-Stop schwenk- und abstellbar (außerhalb vom Luftstrom).
Düseneinsätze Albuz gelb
- Teleskop Gelenkwelle Walterscheid
- Einseitige Abdeckung zu D 36A - für hohe Kulturen
Zusatzausrüstung
- Myers-Doppel- und Dreifachdüse
- Düseneinsätze nach Wahl
- Magnetventile
Einsatzbereich
- Reihenabstand: 1,6 bis 8,0 Meter
- Kultur-Höhe: bis 12,0 Meter
Universelle Achsregelbaugruppe (Positionsregelung und
Druckregelung) mit Feldbus IO-Ankopplung und SSI-Sensorschnittstelle, erhältlich mit EtherCAT-, Profinet- oder Profibus-Anbindung
R134a is internationally recognizcd asone of the main refrigerant working substances to substitute CTC 12. It doesnot contain chlorine atom, gives no bad effects against ozonosphere and hasexcellent safety performances, such as noninflammability, non-explosiveability, non-toxicity, non-pungency, and non-corrosive ability. It is acolorless gas under ordinary temperature and a colorless & transparentliguid under the pressure of itself. As the substitute for crc 12, it is oftenused in the refrigerating systems of auto air conditioners, commercial ancindustrial purposes, and as the vesicant, it is used to produce theheat-protective material made of rigid plastics, and also to prepare otherblend refrigerants, such as R404A & R407C.
SKU:TH675GL7X13690
Model:67010
Package Dimensions:18.25 x 12.32 x 10.75 inches
Exterior:Steel, brass
Voltage:12 Volts
The SAE J1939 standard (Serial Control and Communications Heavy Duity Vehicle Network) has originally been designed by SAE International to be used in heavy duty vehicles. In the meantime, the protocol is widely used also in agricultural machinery, rail vehicles and sea vessels and in a wide range of diesel-driven machinery.
Target group J1939 training
The target group of the J1939 intensive workshop is development engineers who are looking for a quick start into handling the communications profile or would like to get an insight into the J1939 protocol stack. Also, we address decision makers and product managers to enable them to assess the suitability of the J1939 protocol stack for their applications.
• According to DIN EN 61810-1, DIN EN 60664-1
• Low rated power consumption
• 2 changeover contacts
• Clearance and creepage distances:
contact - coil ≥ 8 mm
• Adjustment to customers specification
• Compact size, small height (at horizontal model)
• OA 5661.12 horizontal mounting
• OA 5662.12 vertical mounting
• Solder line proof
Function:Printed circuit board relay
Type of relay:monostabil
Contact material:AgSnO2; AgNi
Continuous current:6 A
Nominal voltage UN DC:6 - 60 V
Voltage Range UN:0,7 - 1,4 V
Test voltage (AC) contact set - coil:≥ 4 kV eff
Clearance and creepage distances, contact set - coil ≥:8 mm
Temperature range (- / +):40 - 70 °C
Protection type:RT II (flux-proof relay)
Size L x W x H:37 x 25 x 10,8 mm
Approvals:cRUus
Relay type:OA 5661.12
The modul µCAN.4.ao-SNAP features four independent analogue outputs which optionally provide a voltage or a current signal. The CAN interface supports CANopen and J1939 protocols.
Voltage +/- 10 V:Current 0(4)…20 mA
Accuracy 0.05 % (FS):Resolution 16-bit (1 mV / 1 µA)
Signal output 1 ms / 1 kHz:Signal type freely configurable
Fieldbus CAN:Protocol CANopen / Raw CAN / J1939
CT-222F 16 channel digital output/24VDC/source type/output 24VDC, the output high level is valid
Module features
the module supports 16 channels digital output, the output high level is valid, the output voltage is 24VDC.
module can drive field equipment. (relay, solenoid valve, etc.)
the internal bus of the module and field output are using opto-coupler.
the module has 16 digital output channel LED indicator light.
the module has the functions of thermal shutdown and overcurrent protection.
the module supports short circuit protection and overload protection.
Wiring:Max.1.5mm²(AWG 16)
Mounting Type:35mm Size DIN-Rail
Size:115*51.5*75mm
Weight:65g
Operation Temperature:-40~85
Protection Class:IP20
Operational Humidity:5%~95% RH(No Condensation)
Product Model:CT-222F